Protection
[back to top] |
Other
ISP
Products
|
Ideal for
equipment with a figure '8' IEC power sockets this plugs between the IEC
socket and the IEC plug and lead supplied with your equipment. This device
dissipates incoming and outgoing surges to and from domestic and professional
equipment. Power consumption is minimal and reset is automatic.
|
 |
|
Applications
[back to top] |
|
Lap Top Computers Hi-fi
Computer peripherals Audio Equipment Video recorders and many other
applications using the figure '8' IEC power inlet connector |
Every
Inline Surge Protector is tested to ensure very fast operation and minimum let
through voltage. The unit appears invisible to the mains filter fitted inside
modern electronic equipment. This state of the art patented product provides
cost effective mains transient protection. |
|
Specifications
[back to top]
|
|
Power Consumption |
0.6 Amps |
|
BS6651 1992 Appendix C Location Category |
A and B |
|
Dimension (in mm) |
L 80, W 37, H 27 |
|
Weight (in grams) |
60 |
|
Order Code |
ISP3/BOW-CP |
|
Surge Handling Capability: |
5Kv (1.2/50us O/C) @ 2-5kA (8/20us S/C)
Let through voltage <900V
6Kv (0.5us/100kHz Ring Wave) @ 500A (S/C) Let through
voltage <900V |
|
BS6651 1992 Appendix C Location Category |
A-high/B-medium |
|
Earth Leakage (typ.) |
N/A (class 2 product) |
|
Operating temperature |
-5 to +40 (celcius) (normal range) |
|
Enclosure |
Flame retardant thermon plastic (light grey) |
|
Dimension (in mm) |
L 60 / W 32 / D 18 |
|
Weight (in grams) |
16 |
|
Order Code |
ISP4/BOW |
|
|
Features
[back to top] |
- Rated
2.5 Amps
- Cool
grey flame retardant moulding
-
Protection operational indictator light
- Thermal
overload protection
|
The ISP4 has a
neon light which indicates protection operational. The light will extinguish
should a high energy strike destroy the internal protector, however power will
still be supplied to the associated equipment. Should the light go out the
unit must be replaced to restore surge protection. |
|
Regulations
[back to top] |
- This product has a 'failsafe' arrangement of surge protection
to guarantee the thermal link blows and indicates failure unlike
the arrangement used by most of our competitors which could mean
the loss of protection without indication thus leaving your
equipment exposed to further surge damage.
- Thermal overload protection fitted as standard. Surge
protection products where protection elements are not fitted with
this safety feature can overheat under fault conditions, and give
rise to the risk of electric shock or fire.
|
- Satisfies
the recommendations of BS6651 1991 Appendix C
- Protection
elements comply with the latest issue of UL 1449 Transient Voltage
Surge Suppressors (August 1996)
- Tested
against 'worst case' conditions as defined in International
Standards IEEE C62.41 - 1991 Cat B2 (test wave 8/20us)
- Complies